Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Heart ; 109(15): 1153-1158, 2023 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-37147129

RESUMEN

OBJECTIVES: To describe the aortic-related risks associated with pregnancy in women with bicuspid aortic valve (BAV) and to evaluate changes in aortic diameter in pregnancy. METHODS: Prospective observational study of patients with BAV from a single-site registry of pregnant women with structural heart disease between 2013 and 2020. Cardiac, obstetric and neonatal outcomes were studied. An assessment of aortic dimensions was performed during pregnancy by two-dimensional echocardiography. Aortic diameters were measured at the annulus, root, sinotubular junction and maximum ascending aorta diameter, and the largest diameter was used. Measurements of the aorta were made using the end-diastolic leading edge-to-leading edge convention. RESULTS: Forty-three women (32.9 years, IQR 29.6-35.3) with BAV were included: 9 (20.9%) had repaired aortic coarctation; 23 (53.5%) had moderate or severe aortic valve disease; 5 (11.6%) had a bioprosthetic aortic valve; and 2 (4.7%) had a mechanical prosthetic aortic valve. Twenty (47.0%) were nulliparous. The mean aortic diameter in the first trimester was 38.5 (SD 4.9) mm, and that in the third trimester was 38.4 (SD 4.8) mm. Forty (93.0%) women had an aortic diameter of <45 mm; 3 (7.0%) had 45-50 mm; and none had >50 mm. Three women (6.9%) with BAV presented cardiovascular complications during pregnancy or the postpartum period (two prosthetic thrombosis and one heart failure). No aortic complications were reported. There was a small but significant increase in aortic diameter during pregnancy (third trimester vs first trimester, 0.52 (SD 1.08) mm; p=0.03). Obstetric complications appeared in seven (16.3%) of pregnancies, and there were no maternal deaths. Vaginal non-instrumental delivery was performed in 21 (51.2%) out of 41 cases. There were no neonatal deaths, and the mean newborn weight was 3130 g (95% CI 2652 to 3380). CONCLUSIONS: Pregnancy in BAV women had a low rate of cardiac complications with no aortic complications observed in a small study group. Neither aortic dissection nor need for aortic surgery was reported. A low but significant aortic growth was observed during pregnancy. Although requiring follow-up, the risk of aortic complications in pregnant women with BAV and aortic diameters of <45 mm at baseline is low.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Embarazo , Recién Nacido , Humanos , Femenino , Masculino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos
2.
Front Cardiovasc Med ; 9: 838473, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35282384

RESUMEN

Objective: To analyze if there are sex-related differences in patients with unexplained syncope and bundle branch block (BBB). Background: Despite increasing awareness that sex is a major determinant of the incidence, etiology, and the outcomes of different arrhythmias, no studies have examined differences in presentation and outcomes between men and women with syncope and BBB. Methods: Cohort study of consecutive patients with unexplained syncope and BBB was included from January 2010 to January 2021 with a median follow-up time of 3.4 years [interquartile range (IQR) 1.7-6.0 years]. They were evaluated by a stepwise workup protocol based on electrophysiological study (EPS) and long-term follow-up with an implantable cardiac monitor (ICM). Results: Of the 443 patients included in the study, 165 (37.2%) were women. Compared with men, women had less diabetes (25.5 vs. 39.9%, p = 0.002) and less history of ischemic heart disease (IHD; 13.3 vs. 25.9%, p = 0.002). Left bundle branch block (LBBB) was more frequent in women (55.2 vs. 27.7%, p < 0.001) while right bundle branch block (RBBB) was more frequent in men (41.5 vs. 67.7%, p < 0.001). His to ventricle (HV) interval in the EPS was shorter in women (58 ms [IQR 52-71] vs. 60 ms [IQR 52-73], p = 0.035) and less women had an HV interval longer than 70 ms (28.5 vs. 38.1%, p = 0.039), however, EPS and ICM offered a similar diagnostic yield in both sexes (40.6 vs. 48.9% and 48.4% vs. 51.1%, respectively). Women had a lower risk of developing atrioventricular block (AVB) (adjusted odds ratio [OR] 0.44-95% CI 0.26-0.74, p = 0.002) and of requiring permanent pacemaker implantation (adjusted hazard ratio [HR] 0.72-95% CI: 0.52-0.99, p = 0.046). The mortality rate was lower in women (4.5 per 100 person-years [95% CI 3.1-6.4 per 100 person-years] vs. 7.3 per 100 person-years [95% CI 5.9-9.1 per 100 person-years]). Conclusions: Compared to men, women with unexplained syncope and BBB have a lower risk of AVB and of requiring cardiac pacing. A stepwise diagnostic approach has a similar diagnostic yield in both sexes, and it seems appropriate to guide the treatment and avoid unnecessary pacemaker implantation, especially in women.

3.
World J Cardiol ; 13(11): 608-627, 2021 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-34909127

RESUMEN

Palpitations are one of the most common reasons for medical consultation. They tend to worry patients and can affect their quality of life. They are often a symptom associated with cardiac rhythm disorders, although there are other etiologies. For diagnosis, it is essential to be able to reliably correlate the symptoms with an electrocardiographic record allowing the identification or ruling out of a possible rhythm disorder. However, reaching a diagnosis is not always simple, given that they tend to be transitory symptoms and the patient is frequently asymptomatic at the time of assessment. In recent years, electrocardiographic monitoring systems have incorporated many technical improvements that solve several of the 24-h Holter monitor limitations. The objective of this review is to provide an update on the different monitoring methods currently available, remarking their indications and limitations, to help healthcare professionals to appropriately select and use them in the work-up of patients with palpitations.

4.
Heart Rhythm ; 18(4): 597-604, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33326869

RESUMEN

BACKGROUND: Syncope in patients with mid-range left ventricular ejection fraction (LVEF) can be due to potentially serious arrhythmic causes. However, there is no clear consensus on the best way to manage these patients. OBJECTIVES: The objectives of this study were to determine the causes of syncope and assess the diagnostic yield and safety of a stepwise workup protocol in this population. METHODS: This was a prospective observational study. A stepwise workup protocol was applied to patients with LVEF 35%-50% and unexplained syncope after the initial assessment (step 1). RESULTS: One hundred four patients were included {median age 75.6 years; (interquartile range [IQR] 67.6-81.2 years); median LVEF 45% (IQR 40%-48%); median follow-up 2.0 years (IQR 0.7-3.3 years). In 71 patients (68.3%), a diagnosis was reached: 55 (77.5%) in step 2 (hospital admission and electrophysiology study) and 16 (36.5%) in step 3 (implantable cardiac monitor). Arrhythmic causes were the most common etiology (45.2% auriculoventricular block and 9.6% ventricular tachycardia). Sixty patients (57.7%) required the implantation of a cardiac device and 11 had a defibrillation function. Patients diagnosed in step 3 had a higher global risk of recurrence of syncope (hazard ratio 6.5; 95% confidence interval 2.3-18.0). The mortality rate was 8.1 per 100 person-years, and the sudden or unknown death rate was 0.9 per 100 person-years. CONCLUSION: In patients with mid-range left ventricular dysfunction and syncope of unknown cause, a systematic diagnostic strategy based on electrophysiology study and/or implantable cardiac monitor implantation allows a diagnosis to be reached in a high proportion of cases and guides the treatment. Arrhythmia is the most common cause of syncope in this population, particularly auriculoventricular block.


Asunto(s)
Electrocardiografía/métodos , Medición de Riesgo/métodos , Síncope/etiología , Disfunción Ventricular Izquierda/etiología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Incidencia , Masculino , Pronóstico , Estudios Prospectivos , Factores de Riesgo , España/epidemiología , Tasa de Supervivencia/tendencias , Síncope/diagnóstico , Síncope/epidemiología , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/epidemiología
5.
Int J Cardiol ; 316: 110-116, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32470530

RESUMEN

OBJECTIVE: The use of implantable cardiac monitors (ICM) is highly useful in syncope workup. Latest-generation devices can detect asymptomatic episodes of atrial fibrillation. The main objective of this study was to determine the incidence of subclinical atrial fibrillation (AF) detected in a patient population undergoing prolonged electrocardiographic monitoring with an ICM for the etiological workup of syncope. METHODS: Prospective observational study carried out in a tertiary hospital from April 2014 to October 2019. All consecutive adult patients monitored with a latest-generation ICM for syncope with no prior history of AF were included in the analysis. RESULTS: Of a total of 509 ICMs implanted during the study period, 208 patients fulfilled the inclusion criteria. 42 patients (20.2%) were found to have AF on ICM. The incidence of AF was 11.7 cases per 100 person-years (95% CI: 8.7-15.9 per 100 person-years). The median burden of AF was 0.2% (IQR 0-0.8%). Age, the presence of hypertension, chronic kidney disease, the size of the septum and left atrium on electrocardiogram and the presence of broad QRS on baseline electrocardiogram were predictors for the appearance of AF in the univariate analysis. CONCLUSION: The incidental finding of atrial fibrillation in patients with syncope monitored with ICM is common. The burden of AF is low, and it is generally subclinical. These findings create added value for the use of ICM in the workup for syncope, although further studies are needed to determine the clinical benefit of documenting subclinical AF.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Adulto , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Electrocardiografía , Electrocardiografía Ambulatoria , Humanos , Incidencia , Síncope/diagnóstico , Síncope/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...